The Future in a Construction. WorldWide.

Modular Systems for Ventilated Façades

An industrialised modular ventilated façade system is a high-performance prefabricated enclosure for buildings that combines the benefits of industrialised construction (high quality, speed, precision) with a ventilated façade (air chamber for insulation and moisture reduction) in a single product that is installed on site. These panels integrate structure, insulation and our ceramic finishes, optimising the energy efficiency, durability and aesthetics of the building.

FV-LAMA SERIES

Slat Module

Self-supporting “brise-soleil” system consisting of extruded slats of varied sections, fixed to a metal frame available in a wide range of finishes. The slats alternate different tones, from traditional soft and reddish earth tones to the most innovative enamels, to create a chromatic rhythm and at the same time effect effective solar control. It is installed between floors, ready to anchor using adjustable brackets, providing solar protection, privacy and a marked architectural character.

Ceramic technical details

Maximum length

1500mm

Tolerances

ISO 10545-2

Length (Extrusion Direction) ± ± 1mm*
Height ± ± 2mm*
Thickness ± ± 10%*
Straightness (Extrusion Direction) ± ± 0.3% of the length
Orthogonality ± ± 1% of the height
Surface Flatness ± 0.5% diagonal or height

Water absorption

ISO 10545-3

1% or 3-6% depending on color

Flexural strength

ISO 10545-4

FVC 15-20 N/mm
FVB 14-18 N/mm depending on color

Linear thermal expansion

ISO 10545-8

Coefficient of expansion 5.7 x 10 6 [K 1]
ITC Test

Thermal shock resistance

ISO 10545-9

According to testing, unalterable up to 145°C

Moisture expansion

ISO 10545-10

Average value 0.1 mm/m,
maximum value 0.1mm/m. ITC Test

Frost resistance

ISO 10545-12

Unalterable according to test [100 cycles + 5°C to -5°C]

Chemical resistance

ISO 10545-13

Only applies in corrosive conditions Minimum class G and B

Stain resistance

ISO 10545-14

Minimum class 3

Color differences

ISO 10545-16

AE 2

Module technical details

Module thickness (mm)

80 up to 180

Horizontal format (max)

6m x 3.2m

Vertical format (min)

1.50m x 3.20m

Fixings

Hidden

Reaction to fire

A1

Internal structure

CE

Design criteria

CTE

USES

Structure adaptable to position between and above floors

FV-ACQUA SERIES

Ceramic Tile Module

Ventilated facade element that combines large extruded plates with a smooth or volumetric texture. The prefabricated element integrates a window subframe and insulation, guaranteeing flatness and tolerances of an industrialized facade. A wide range of finishes that facilitate combination with other materials and enhance the main facade lines, providing a contemporary and minimalist aesthetic with precise, fast and efficient assembly.

Ceramic technical details

Maximum length

1500mm

Maximum width

600mm

Tolerances

ISO 10545-2

Length (Extrusion Direction) ± ± 1mm*
Height ± ± 2mm*
Thickness ± ± 10%*
Straightness (Extrusion Direction) ± ± 0.3% of the length
Orthogonality ± ± 1% of the height
Surface Flatness ± 0.5% diagonal or height

Water absorption

ISO 10545-3

1% or 3-6% depending on the color

Flexural strength

ISO 10545-4

FVC 15-20 N/mm2 – FVB 14-18 N/mm2 depending on color

Linear thermal expansion

ISO 10545-8

Coefficient of expansion 5.7 x 10-6 (K-1). ITC test

Thermal shock resistance

ISO 10545-9

According to testing, unalterable up to 145°C

Moisture expansion

ISO 10545-10

Average value ‘0.1 mm/m, maximum value ‘0.1 mm/m. ITC test

Frost resistance

ISO 10545-12

Unalterable according to test (100 cycles + 5ºC to -5ºC)

Chemical resistance

ISO 10545-13

Only applicable in corrosive conditions. At least class G and B.

Stain resistance

ISO 10545-14

At least CLASS 3

Color differences

ISO 10545-16

∆E 2

Module technical details

Module thickness (mm)

170 up to 360

Horizontal format

6m x 3.2m

Vertical format

2.40m x 5m

Geometry

Flat or volumetric

Fixings

Hidden

Thermal insulation

U=0.17 -V 0.40 w/mK

Watertightness to rainwater

Class E1050

Air permeability

Class 4

Fire resistance

EI 120

Reaction to fire

A1

Internal structure

CE

Reaction to fire

CTE

Uses

New construction and renovation

Structure adaptable to position between joists and on joists

Coupling

New construction and renovation

Tongue and groove/flat

Renovation

Tongue and groove/flat

FV-BRICKTILE SERIES

Ceramic Tile Module – Brick Style

Prefabricated panel with small-format extruded tiles arranged with continuous joints in multiple finishes. It incorporates a fully pre-assembled window opening, with integrated metal jambs, lintel and sill, achieving a continuous surface without on-site finishes. Ideal for giving a traditional factory appearance with the speed of a “plug play” system.

Ceramic technical details

Tolerances

ISO 10545-2

Length (Extrusion Direction) 3 ± 1mm*
Height 3 ± 2mm*
Thickness 3 ± 10%*
Straightness (Extrusion Direction) 3 ± 0.3% of the length
Orthogonality 3 ± 1% of the height
Surface Flatness ± 0.5% diagonal or height

Water absorption

ISO 10545-3

1% or 3-6% depending on the color

Flexural strength

ISO 10545-4

FVC 15-20 N/mm2 – FVB 14-18 N/mm2 depending on color

Linear thermal expansion

ISO 10545-8

Coefficient of expansion 5.7 x 10-6 (K-1). ITC test

Thermal shock resistance

ISO 10545-9

According to testing, unalterable up to 145°C

Moisture expansion

ISO 10545-10

Average value ‘0.1 mm/m, maximum value ‘0.1 mm/m. ITC test

Frost resistance

ISO 10545-12

Unalterable according to test (100 cycles + 5ºC to -5ºC)

Chemical resistance

ISO 10545-13

Only applies in corrosive conditions Minimum class G and B

Stain resistance

ISO 10545-14

At least CLASS 3

Color differences

ISO 10545-16

∆E 2

Module technical details

Module thickness (mm)

170 up to 360

Horizontal format

6m x 3.2m

Vertical format

2.40m x 5m

Geometry

Flat or volumetric

Fixings

Hidden

Thermal insulation

U=0.17 -V 0.40 w/mK

Watertightness to rainwater

Class E1050

Air permeability

Class 4

Fire resistance

EI 120

Reaction to fire

A1

Internal structure

CE

Reaction to fire

CTE

Uses

New construction and renovation

Structure adaptable to position between joists and on joists

Coupling

New construction and renovation

Tongue and groove/flat

Renovation

Tongue and groove/flat

FV-BRIKTILE 3D SERIES

Three-Dimensional Module – Brick Style

Volumetric panel that incorporates a relief of pilasters and vertical openings, generated from imitation brick tiles. The staggered depths between the different facade panels add dynamism and improve passive solar performance by creating integrated eaves. It includes a supporting substructure, continuous insulation and already placed carpentry, making it a comprehensive solution ready to hoist and fix directly to the building structure, reducing construction times and improving the final quality.

Ceramic technical details

Tolerances

ISO 10545-2

Length (Extrusion Direction) ± ± 1mm*
Height ± ± 2mm*
Thickness ± ± 10%*
Straightness (Extrusion Direction) ± ± 0.3% of the length
Orthogonality ± ± 1% of the height
Surface Flatness ± 0.5% diagonal or height

Water absorption

ISO 10545-3

1% or 3-6% depending on the color

Flexural strength

ISO 10545-4

FVC 15-20 N/mm2 – FVB 14-18 N/mm2 depending on color

Linear thermal expansion

ISO 10545-8

Coefficient of expansion 5.7 x 10-6 (K-1). ITC test

Thermal shock resistance

ISO 10545-9

Unalterable up to 145ºC, according to test

Moisture expansion

ISO 10545-10

Average value ‘0.1 mm/m, maximum value ‘0.1 mm/m. ITC test

Frost resistance

ISO 10545-12

Unalterable according to test (100 cycles + 5ºC to -5ºC)

Chemical resistance

ISO 10545-13

Only applicable in corrosive conditions. At least class G and B.

Stain resistance

ISO 10545-14

At least CLASS 3

Color differences

ISO 10545-16

∆E 2

Module technical details

Maximum length

1000mm

Module thickness

70mm

Flexibility in size

Horizontal format

Variety in ceramic piece geometries

Fixings

Hidden

Thermal conductivity

=0.035 W/(m*K)

Minimum flexural strength

BS=150 MPa

Resistance to water vapor diffusion

= 30-70

Dimensional stability in N. C.

±0’2mm

Uses

New construction and renovation

Structure adaptable to position between joists and on joists

Coupling

New construction and renovation

Position on existing factory enclosure

Basic evaluation
by the architect

Project evaluation and
preliminary design

Development of technical
documentation for execution

Project
implementation

Contact us

let's work together

Do you have any questions or requests? We're here to help.

Ctra. Herrera de los Navarros, km. 1,5
50450, Muel, Zaragoza, Spain

(+34 ) 976 140 311 | (+34 ) 976 141 164

export@faveton.com